<LOGO>
FM Transmitter Measurement Report
Created: 2024-09-02 08-48-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.20 MHz 5/5, 58 dBuV "" "
Pilot RDS Phase Difference
7.0 kHz 2.8 kHz 27 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 68 kHz 18281 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,2 dBr 5,90 dBr 6,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"" " 6459 25 (Country) 1 0 1 1 --:--
RT
"J Balvin - Mi Gente Feat. Willy William "
AF EON
92.9, 94.8, 98.3, 105.1, 106.1, 106.2 MHz -
FM Scope Max at: 68 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/09/02 8.47.22 Total samples: 18281 Equivalent time: 0:15:14 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,9 dBr MIN: 4,2 dBr AVE: 5,90 dBr % above 12,2 dBr: 0,0 Last value: 6,2 dBr (2024/09/02 8.47.22) 08.34 08.36 08.38 08.40 08.42 08.44 08.46 0 2 4 6 Pm [dBr]